Siemens Gigaset

From Hackerspace ACKspace
Revision as of 17:09, 29 November 2016 by Xopr (talk | contribs) (updated settings to trigger SRV compatibility)
Jump to: navigation, search

general info

N510 IP PRO

  • manual
  • Runs on 6.5V (1.2-1.3W)
  • supports 6 GAP handsets
  • 6 handsets
  • up to 4 simultaneous calls
  • Supports IEEE802.3af (PoE)
  • Info Center support (TBD)

Also did a test with the Ubiquiti passive 24v PoE (Pairs 4 & 5+, 7 & 8 -); it doesn't work.

The device supports two distinctive rings; default (extenal) and alert-internal:

Alert-Info: <http://www.notused.com>;info=alert-internal

Exposed internals:

connecting the N510 IP PRO

Under Settings » Telephony » Connection, the following settings are needed:

  • Connection name or number: <anything>
  • Provider: Other provider
  • Authentication name: <username>
  • Authentication password: <password>
  • Username: <username>
  • Display name: <anything>
  • Lookup Enabled (if available, version ≥ 240): yes
  • Domain: ackspace.nl
  • Registration server: <leave empty>
  • Proxy server address: <leave empty>
  • Proxy server port: <leave empty to trigger SRV lookup>
  • Registration server: <leave empty>
  • Registration server port: <leave empty to trigger SRV lookup>
  • Registration refresh time: 110
  • STUN enabled: Yes
  • STUN server address: stun.ekiga.net
  • STUN server port: 3478
  • STUN refresh time: 240
  • Outbound proxy mode: Automatic
  • Outbound proxy port: <leave empty to trigger SRV lookup>
  • Select network protocol: Automatic
Note that these settings take a while for the Gigaset to connecto to the right server.
Also, make sure that under Settings » Telephony » Advanced VoIP settings, SIP port: (or its random range) does not conflict with other SIP devices behind the same NAT.