Difference between revisions of "Polycom"
m (found a "shortcut") |
m (Fixed typo) |
||
Line 33: | Line 33: | ||
To get its IP: Press {{k|🏠}}, go down 2 times (Settings ⚙️), Ok (joypad center), {{k|4}},{{k|2}},{{k|1}} (Status, Network, TCP/IP Parameters) | To get its IP: Press {{k|🏠}}, go down 2 times (Settings ⚙️), Ok (joypad center), {{k|4}},{{k|2}},{{k|1}} (Status, Network, TCP/IP Parameters) | ||
− | Under '''Settings''' » '''SIP''' » ''' | + | Under '''Settings''' » '''SIP''' » '''Local Settings''', the following settings are needed (note that a '''Simple Setup''' will get you started as well): |
* '''Local SIP Port:''' <make sure this port does not conflict with other SIP devices behind the same NAT>, 0 seems to work as well | * '''Local SIP Port:''' <make sure this port does not conflict with other SIP devices behind the same NAT>, 0 seems to work as well | ||
* '''Digit Map:''' <code>1[01579]xS0{{!}}1[23]xxS0{{!}}5000S0{{!}}2xxS0{{!}}00x.{{!}}0[1234567]xxxxxxxxS0{{!}}088xxxxxxxS0{{!}}0800xxxx.{{!}}090[069]xxxx.</code> | * '''Digit Map:''' <code>1[01579]xS0{{!}}1[23]xxS0{{!}}5000S0{{!}}2xxS0{{!}}00x.{{!}}0[1234567]xxxxxxxxS0{{!}}088xxxxxxxS0{{!}}0800xxxx.{{!}}090[069]xxxx.</code> |
Revision as of 07:57, 8 April 2022
Power (over Ethernet) compatibility:
barrel plug: 5.5/2.5 48V
straight | crosslink | |
---|---|---|
802.3af | yes | unknown |
legacy | unknown | unknown |
compatible | unknown | unknown |
Unifi | unknown | unknown |
Note:
VVX 301
- Default passcode:
456
- This device can handle 401: unauthorized
- has a boot time of about 140 seconds!
- webinterface available at https://<ip>
- has 6P6C (RJ12) AUX port
- has 5 pin (0.1" 3x2 with notch) female header
- has unpopulated internal 2 pin header (J300) seen through the upper slot
- both AUX and header pins 5 are connected (GND?): RJ12 second right, header, first left at the top
factory reset
- power up the phone
- Wait for
Starting application. press Cancel to interrupt
and press Cancel (right softbutton) - at the countdown screen, press and hold 1+5+3 for >3 seconds
- enter the MAC address located near the connectors (without colons) as password (old style sms-mode; note that for entering digits or characters, you need to set the correct input type. Also it's not case sensitive. Button 2 will show you the current mode and next mode)
connecting the Polycom VVX 301
To get its IP: Press 🏠, go down 2 times (Settings ⚙️), Ok (joypad center), 4,2,1 (Status, Network, TCP/IP Parameters)
Under Settings » SIP » Local Settings, the following settings are needed (note that a Simple Setup will get you started as well):
- Local SIP Port: <make sure this port does not conflict with other SIP devices behind the same NAT>, 0 seems to work as well
- Digit Map:
1[01579]xS0|1[23]xxS0|5000S0|2xxS0|00x.|0[1234567]xxxxxxxxS0|088xxxxxxxS0|0800xxxx.|090[069]xxxx.
- Server 1 » Address: ackspace.nl
- Transport: DNSnaptr1
- Expires (s): 110
Under Lines » Line 1, set the following:
- Identification » Display Name: <anything>
- Identification » Label: <anything for local display>
- Identification » Address: <username>@ackspace.nl
- Authentication » User ID: <username>
- Authentication » Password: <password>
1) or use: TCPpreferred and set Outbound Proxy » Address to sip.ackspace.nl (not tested)
TODO
- minimum web-setup
- AUX port pinout
- deployment server