Avaya

From Hackerspace ACKspace
Revision as of 17:33, 22 April 2023 by Xopr (talk | contribs) (fixed TOC transclusion)
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Jump to: navigation, search

1608

Power (over Ethernet) compatibility:
barrel plug: 5.5/2.5 5V

straight crosslink
802.3af yes unknown
legacy unknown unknown
compatible unknown unknown
Unifi unknown unknown

Note:

  • H.323 only
  • default password 27238 (craft)

4620SW

Avaya 4620SW
  • only uses pins 1,2,3 + 6 (100Base-T)
  • PoE compatible
  • custom power module available: GND:pin 7, +48V:pin 8
  • upon booting (about 20 seconds), the following message appears:
    100 mbps ethernet (you might want to unplug the ethernet cable if the keys do not respond)
    * to program (after this step, you can plug in the ethernet connection again so you are able to type in the SIG command at the end)
  • press *
  • confirm every default with # (8x)
  • at the end, it says "No new values. #=OK": confirm
  • at the blank screen, type mute744# (Mute SIG#, you will notice a distinct short tick when pressing mute, and other keys being silent)
  • change to SIP by cycling using * and confirm using #
  • default password 27238 (craft)

You will need a TFTP server and the 46xxSettings.txt file (see Avaya's sample and a snippet from LeftyBC on github gist

Power (over Ethernet) compatibility:
barrel plug: none

straight crosslink
802.3af yes yes
legacy no no
compatible yes yes
Unifi unknown unknown

Note:

9608

Avaya 9608

9611

Power (over Ethernet) compatibility:
barrel plug: none

straight crosslink
802.3af yes unknown
legacy unknown unknown
compatible unknown unknown
Unifi unknown unknown

Note:

  • default password 27238 (craft)

9650

Avaya 9650
  • default password 27238 (craft)
  • latest supported SIP firmware version seems to be 2.6.17.0
  • also uses 46xxsettings.txt
    • $MACADDR is not usable in the config file
    • SKINS and CURRENT_SKIN doesn't work
    • CURRENT_CONTENT works: even the option of adding hidden menus
    • CURRENT_LOGO doesn't work
    • SET SIP_CONTROLLER_LIST is most likely numeric
    • no support for FORCE_SIP_*
  • 8+1 auxiliary buttons are not programmable, only the 3 appLines, 4 softKeys and 5 hardButtons (calllog, contacts amenu, message, forward)
  • doesn't handle 401 Unauthorized
  • xopr had problems with ACK/BYE from the phone (it never hangs up and some calls will disconnect after ~30 seconds)


Power (over Ethernet) compatibility:
barrel plug: none

straight crosslink
802.3af yes yes
legacy no no
compatible yes yes
Unifi unknown unknown

Note: Location: xopr's (project crate and a bunch at home)


B189

Power (over Ethernet) compatibility:
barrel plug: none

straight crosslink
802.3af yes unknown
legacy unknown unknown
compatible unknown unknown
Unifi unknown unknown

Note: Features:

  • default password 27238 (craft)
  • H.323 only
  • color touchscreen
  • Gigabit ethernet (single port)
  • Has mini USB: it doesn't power the device, it doesn't enumerate on the PC correctly and is marked "for future use" in the manual. Also booting with several button combinations didn't triger a valid USB port