Difference between revisions of "Siemens Gigaset"

From Hackerspace ACKspace
Jump to: navigation, search
m (removed dummy device, added bookmark link)
m (added category)
 
(6 intermediate revisions by the same user not shown)
Line 1: Line 1:
 +
== general info ==
 +
* The Targa DIP phone 450 (Sold years ago at Lidl) uses the same firmware as the SIEMENS Gigaset C450 IP but has different hardware (See [http://www.voip-info.org/wiki/view/Siemens+Gigaset+C450IP voip-info.org] and [https://github.com/neffs/gigahack/issues/1#issuecomment-36466764 github issue])
 +
* T-Home Sinus 501V also was a rebrand of Gigaset
 +
* Interesting links:
 +
** https://github.com/neffs/gigahack
 +
** https://teamwork.gigaset.com/gigawiki/pages/viewpage.action?pageId=28540959
 +
 
== N510 IP PRO ==
 
== N510 IP PRO ==
 +
* [http://gse.gigaset.com/fileadmin/legacy-assets/A31008-M2217-R101-3-7619_en.pdf manual]
 +
* Runs on 6.5V (1.2-1.3W)
 
* supports 6 GAP handsets
 
* supports 6 GAP handsets
 
* 6 handsets
 
* 6 handsets
 
* up to 4 simultaneous calls
 
* up to 4 simultaneous calls
 +
* Supports IEEE802.3af (<abbr title="Power over Ethernet">PoE</abbr>)
 +
* Info Center support (TBD)
 +
 +
{{PoE
 +
|Barrel_plug=unknown
 +
|Barrel_voltage=6.5V
 +
|802:3af_straight=yes
 +
|802:3af_crosslink=yes
 +
|Legacy_straight=no
 +
|Legacy_crosslink=no
 +
|Compatible_straight=yes
 +
|Compatible_crosslink=yes
 +
|Unifi_straight=no
 +
|Unifi_crosslink=no
 +
|Note=
 +
}}
 +
 +
The device [https://teamwork.gigaset.com/gigawiki/display/GPPPO/FAQ+Distinctive+Ringing+protocol supports two distinctive rings]; default (extenal) and alert-internal:
 +
<pre>Alert-Info: <http://www.notused.com>;info=alert-internal</pre>
 +
 +
Exposed internals:
 +
<gallery>
 +
File:N510_front.jpg|PCB front (where the button goes on top of the led on the center bottom) Blurry image, sorry
 +
File:N510_back.jpg|PCB back
 +
File:N510_front_case.jpg|Note the clips to open the case
 +
File:N510_back_case.jpg|Note the pins to open the case
 +
</gallery>
  
 
<onlyinclude>{{#ifeq:{{{transcludesection|connecting_N510_IP_PRO}}}|connecting_N510_IP_PRO|
 
<onlyinclude>{{#ifeq:{{{transcludesection|connecting_N510_IP_PRO}}}|connecting_N510_IP_PRO|
 
=== connecting the [[Siemens_Gigaset#N510_IP_PRO|N510 IP PRO]] ===
 
=== connecting the [[Siemens_Gigaset#N510_IP_PRO|N510 IP PRO]] ===
The following settiings are needed:
+
Under '''Settings''' &raquo; '''Telephony''' &raquo; '''Connection''', the following settings are needed:
* TBD
+
* '''Connection name or number:''' &lt;anything&gt;
 +
* '''Provider:''' Other provider
 +
* '''Authentication name:''' &lt;username&gt;
 +
* '''Authentication password:''' &lt;password&gt;
 +
* '''Username:''' &lt;username&gt;
 +
* '''Display name:''' &lt;anything&gt;
 +
* '''Lookup Enabled''' (if available, version &ge; 240): yes
 +
* '''Domain:''' ackspace.nl
 +
* '''Registration server: &lt;leave empty&gt;
 +
* '''Proxy server address:''' &lt;leave empty&gt;
 +
* '''Proxy server port:''' &lt;leave empty to trigger SRV lookup&gt;
 +
* '''Registration server:''' &lt;leave empty&gt;
 +
* '''Registration server port:''' &lt;leave empty to trigger SRV lookup&gt;
 +
* '''Registration refresh time:''' 110
 +
* '''STUN enabled:''' Yes
 +
* '''STUN server address:''' stun.ekiga.net
 +
* '''STUN server port:''' 3478
 +
* '''STUN refresh time:''' 240
 +
* '''Outbound proxy mode:''' Automatic
 +
* '''Outbound proxy port:''' &lt;leave empty to trigger SRV lookup&gt;
 +
* '''Select network protocol:''' Automatic
 +
 
 +
:Note that these settings take a while for the Gigaset to connecto to the right server.
 +
:Also, make sure that under '''Settings''' &raquo; '''Telephony''' &raquo; '''Advanced VoIP settings''', '''SIP port:''' (or its random range) does not conflict with other SIP devices behind the same NAT.
 
}}</onlyinclude>
 
}}</onlyinclude>
 +
 +
[[Category:Telephony]][[Category:PoE]]

Latest revision as of 09:56, 14 January 2022

general info

N510 IP PRO

  • manual
  • Runs on 6.5V (1.2-1.3W)
  • supports 6 GAP handsets
  • 6 handsets
  • up to 4 simultaneous calls
  • Supports IEEE802.3af (PoE)
  • Info Center support (TBD)


Power (over Ethernet) compatibility:
barrel plug: unknown 6.5V

straight crosslink
802.3af yes yes
legacy no no
compatible yes yes
Unifi no no

Note:

The device supports two distinctive rings; default (extenal) and alert-internal:

Alert-Info: <http://www.notused.com>;info=alert-internal

Exposed internals:

connecting the N510 IP PRO

Under Settings » Telephony » Connection, the following settings are needed:

  • Connection name or number: <anything>
  • Provider: Other provider
  • Authentication name: <username>
  • Authentication password: <password>
  • Username: <username>
  • Display name: <anything>
  • Lookup Enabled (if available, version ≥ 240): yes
  • Domain: ackspace.nl
  • Registration server: <leave empty>
  • Proxy server address: <leave empty>
  • Proxy server port: <leave empty to trigger SRV lookup>
  • Registration server: <leave empty>
  • Registration server port: <leave empty to trigger SRV lookup>
  • Registration refresh time: 110
  • STUN enabled: Yes
  • STUN server address: stun.ekiga.net
  • STUN server port: 3478
  • STUN refresh time: 240
  • Outbound proxy mode: Automatic
  • Outbound proxy port: <leave empty to trigger SRV lookup>
  • Select network protocol: Automatic
Note that these settings take a while for the Gigaset to connecto to the right server.
Also, make sure that under Settings » Telephony » Advanced VoIP settings, SIP port: (or its random range) does not conflict with other SIP devices behind the same NAT.