Difference between revisions of "Siemens Gigaset"
m (added some information + pictures) |
m (added category) |
||
(4 intermediate revisions by the same user not shown) | |||
Line 1: | Line 1: | ||
+ | == general info == | ||
+ | * The Targa DIP phone 450 (Sold years ago at Lidl) uses the same firmware as the SIEMENS Gigaset C450 IP but has different hardware (See [http://www.voip-info.org/wiki/view/Siemens+Gigaset+C450IP voip-info.org] and [https://github.com/neffs/gigahack/issues/1#issuecomment-36466764 github issue]) | ||
+ | * T-Home Sinus 501V also was a rebrand of Gigaset | ||
+ | * Interesting links: | ||
+ | ** https://github.com/neffs/gigahack | ||
+ | ** https://teamwork.gigaset.com/gigawiki/pages/viewpage.action?pageId=28540959 | ||
+ | |||
== N510 IP PRO == | == N510 IP PRO == | ||
* [http://gse.gigaset.com/fileadmin/legacy-assets/A31008-M2217-R101-3-7619_en.pdf manual] | * [http://gse.gigaset.com/fileadmin/legacy-assets/A31008-M2217-R101-3-7619_en.pdf manual] | ||
Line 8: | Line 15: | ||
* Info Center support (TBD) | * Info Center support (TBD) | ||
− | + | {{PoE | |
+ | |Barrel_plug=unknown | ||
+ | |Barrel_voltage=6.5V | ||
+ | |802:3af_straight=yes | ||
+ | |802:3af_crosslink=yes | ||
+ | |Legacy_straight=no | ||
+ | |Legacy_crosslink=no | ||
+ | |Compatible_straight=yes | ||
+ | |Compatible_crosslink=yes | ||
+ | |Unifi_straight=no | ||
+ | |Unifi_crosslink=no | ||
+ | |Note= | ||
+ | }} | ||
+ | |||
+ | The device [https://teamwork.gigaset.com/gigawiki/display/GPPPO/FAQ+Distinctive+Ringing+protocol supports two distinctive rings]; default (extenal) and alert-internal: | ||
+ | <pre>Alert-Info: <http://www.notused.com>;info=alert-internal</pre> | ||
Exposed internals: | Exposed internals: | ||
Line 27: | Line 49: | ||
* '''Username:''' <username> | * '''Username:''' <username> | ||
* '''Display name:''' <anything> | * '''Display name:''' <anything> | ||
+ | * '''Lookup Enabled''' (if available, version ≥ 240): yes | ||
* '''Domain:''' ackspace.nl | * '''Domain:''' ackspace.nl | ||
− | * '''Registration server: | + | * '''Registration server: <leave empty> |
− | * '''Proxy server port:''' | + | * '''Proxy server address:''' <leave empty> |
+ | * '''Proxy server port:''' <leave empty to trigger SRV lookup> | ||
+ | * '''Registration server:''' <leave empty> | ||
+ | * '''Registration server port:''' <leave empty to trigger SRV lookup> | ||
* '''Registration refresh time:''' 110 | * '''Registration refresh time:''' 110 | ||
* '''STUN enabled:''' Yes | * '''STUN enabled:''' Yes | ||
Line 35: | Line 61: | ||
* '''STUN server port:''' 3478 | * '''STUN server port:''' 3478 | ||
* '''STUN refresh time:''' 240 | * '''STUN refresh time:''' 240 | ||
− | * '''Outbound proxy mode:''' | + | * '''Outbound proxy mode:''' Automatic |
+ | * '''Outbound proxy port:''' <leave empty to trigger SRV lookup> | ||
* '''Select network protocol:''' Automatic | * '''Select network protocol:''' Automatic | ||
− | Also, make sure that under '''Settings''' » '''Telephony''' » '''Advanced VoIP settings''', '''SIP port:''' (or its random range) does not conflict with other SIP devices behind the same NAT. | + | :Note that these settings take a while for the Gigaset to connecto to the right server. |
+ | :Also, make sure that under '''Settings''' » '''Telephony''' » '''Advanced VoIP settings''', '''SIP port:''' (or its random range) does not conflict with other SIP devices behind the same NAT. | ||
}}</onlyinclude> | }}</onlyinclude> | ||
+ | |||
+ | [[Category:Telephony]][[Category:PoE]] |
Latest revision as of 09:56, 14 January 2022
general info
- The Targa DIP phone 450 (Sold years ago at Lidl) uses the same firmware as the SIEMENS Gigaset C450 IP but has different hardware (See voip-info.org and github issue)
- T-Home Sinus 501V also was a rebrand of Gigaset
- Interesting links:
N510 IP PRO
- manual
- Runs on 6.5V (1.2-1.3W)
- supports 6 GAP handsets
- 6 handsets
- up to 4 simultaneous calls
- Supports IEEE802.3af (PoE)
- Info Center support (TBD)
Power (over Ethernet) compatibility:
barrel plug: unknown 6.5V
straight | crosslink | |
---|---|---|
802.3af | yes | yes |
legacy | no | no |
compatible | yes | yes |
Unifi | no | no |
Note:
The device supports two distinctive rings; default (extenal) and alert-internal:
Alert-Info: <http://www.notused.com>;info=alert-internal
Exposed internals:
connecting the N510 IP PRO
Under Settings » Telephony » Connection, the following settings are needed:
- Connection name or number: <anything>
- Provider: Other provider
- Authentication name: <username>
- Authentication password: <password>
- Username: <username>
- Display name: <anything>
- Lookup Enabled (if available, version ≥ 240): yes
- Domain: ackspace.nl
- Registration server: <leave empty>
- Proxy server address: <leave empty>
- Proxy server port: <leave empty to trigger SRV lookup>
- Registration server: <leave empty>
- Registration server port: <leave empty to trigger SRV lookup>
- Registration refresh time: 110
- STUN enabled: Yes
- STUN server address: stun.ekiga.net
- STUN server port: 3478
- STUN refresh time: 240
- Outbound proxy mode: Automatic
- Outbound proxy port: <leave empty to trigger SRV lookup>
- Select network protocol: Automatic
- Note that these settings take a while for the Gigaset to connecto to the right server.
- Also, make sure that under Settings » Telephony » Advanced VoIP settings, SIP port: (or its random range) does not conflict with other SIP devices behind the same NAT.