Difference between revisions of "Siemens Gigaset"

From Hackerspace ACKspace
Jump to: navigation, search
m (updated settings to trigger SRV compatibility)
(added PoE (test) template that shows compatibility tests)
Line 15: Line 15:
 
* Info Center support (TBD)
 
* Info Center support (TBD)
  
Also did a test with the Ubiquiti passive 24v PoE (Pairs 4 & 5+, 7 & 8 -); it doesn't work.
+
{{PoE
 +
|Barrel_plug=unknown
 +
|Barrel_voltage=6.5V
 +
|802:3af_straight=yes
 +
|802:3af_crosslink=yes
 +
|Legacy_straight=no
 +
|Legacy_crosslink=no
 +
|Compatible_straight=yes
 +
|Compatible_crosslink=yes
 +
|Unifi_straight=no
 +
|Unifi_crosslink=no
 +
|Note=
 +
}}
  
 
The device [https://teamwork.gigaset.com/gigawiki/display/GPPPO/FAQ+Distinctive+Ringing+protocol supports two distinctive rings]; default (extenal) and alert-internal:
 
The device [https://teamwork.gigaset.com/gigawiki/display/GPPPO/FAQ+Distinctive+Ringing+protocol supports two distinctive rings]; default (extenal) and alert-internal:

Revision as of 21:10, 13 January 2022

general info

N510 IP PRO

  • manual
  • Runs on 6.5V (1.2-1.3W)
  • supports 6 GAP handsets
  • 6 handsets
  • up to 4 simultaneous calls
  • Supports IEEE802.3af (PoE)
  • Info Center support (TBD)


Power (over Ethernet) compatibility:
barrel plug: unknown 6.5V

straight crosslink
802.3af yes yes
legacy no no
compatible yes yes
Unifi no no

Note:

The device supports two distinctive rings; default (extenal) and alert-internal:

Alert-Info: <http://www.notused.com>;info=alert-internal

Exposed internals:

connecting the N510 IP PRO

Under Settings » Telephony » Connection, the following settings are needed:

  • Connection name or number: <anything>
  • Provider: Other provider
  • Authentication name: <username>
  • Authentication password: <password>
  • Username: <username>
  • Display name: <anything>
  • Lookup Enabled (if available, version ≥ 240): yes
  • Domain: ackspace.nl
  • Registration server: <leave empty>
  • Proxy server address: <leave empty>
  • Proxy server port: <leave empty to trigger SRV lookup>
  • Registration server: <leave empty>
  • Registration server port: <leave empty to trigger SRV lookup>
  • Registration refresh time: 110
  • STUN enabled: Yes
  • STUN server address: stun.ekiga.net
  • STUN server port: 3478
  • STUN refresh time: 240
  • Outbound proxy mode: Automatic
  • Outbound proxy port: <leave empty to trigger SRV lookup>
  • Select network protocol: Automatic
Note that these settings take a while for the Gigaset to connecto to the right server.
Also, make sure that under Settings » Telephony » Advanced VoIP settings, SIP port: (or its random range) does not conflict with other SIP devices behind the same NAT.